4356 Mockingbird Pkwy
Dallas, TX 75205
No carbon monoxide alarms detected near bedrooms
3 gas fireplaces without damper clamps.
Burned/arcing wires at sunroom water heater
Active fire hazard requiring immediate attention.
Water pressure at 90-100 PSI
Maximum safe pressure is 80 PSI. Risk of burst supply lines.
Systems Overview
Roof
50-75 yr remaining
Checked: Mar 27
HVAC (Downstairs)
Delta-T: 0°F (should be 15-20°F)
Checked: Mar 26
Electrical
6 open safety items
Checked: Mar 26
Plumbing
Pressure: 95 PSI (max: 80)
Checked: Mar 26
Structure
Stucco cracking: 3 sides
Checked: Mar 26
Interior
Cosmetic only
Checked: Mar 26
Doors & Windows
3 items, all cosmetic
Checked: Mar 26
Appliances
2 items non-functional
Checked: Mar 26
Recommended Services
Based on your March 2026 assessment
All quotes delivered within 48 hours. 3 competitive bids per service.
CO Alarms & Fireplace Safety
Install CO alarms near bedrooms + damper clamps on 3 gas fireplaces
Water Heater Electrical Repair
Licensed electrician: burned/arcing wires at Bradford White water heater (2011)
Water Heater Replacement
Replace Bradford White 6-gal electric (2011, past design life)
HVAC Downstairs — Warranty Service
Daikin 2023 3-ton: thermostat + diagnostic. Likely under manufacturer warranty.
Electrical Safety Package
Enclose attic junction boxes, proper conduit for exterior wiring, remove extension cord
HVAC Full Service — All 3 Systems
Service all 3 Daikin VRV units, replace rusted drain pan, clean condenser, duct repairs
Water Pressure Regulator
Install pressure reducing valve + expansion tank. Currently 90-100 PSI (max: 80).
Garage Door + Smoke Alarm
Repair garage door opener (failed auto-reverse) + install missing smoke alarm
Stucco Inspection & Repair
Certified stucco inspector moisture probe, then patch/repair 3 elevations
Crawl Space & Foundation
Improve crawl space ventilation, install root barrier, correct east-side drainage
Plumbing Fixtures — 5 Bathrooms
Repair diverters, stoppers, shower door (master), grout repair (master + J&J)
Interior Finishes
Master bath tile, east bedroom flooring, dining room drywall, wet bar repair
Doors & Windows
Adjust sliding glass door, plane sticking doors, replace screens + master lock
Appliance Service
Service/replace wet bar fridge, replace sunroom disposer
Safety First Package
All critical safety items in one coordinated visit (items 1+2+5+8)
HVAC Complete Package
All 3 HVAC systems + warranty claim + duct repairs (items 4+6)
Whole Home Priority Package
Every critical and high-priority item, coordinated sequence
Maintenance Schedule
Expense Monitoring
ActiveElectric bill received — $187 (↓8%)
Pest control renegotiated
Internet rate increase detected
Landscaping invoice — $300
Annual Home Services Spend
$32,400
Optimized Spend
$26,220
Annual Savings
$6,180 (19%)
Accounts Monitored
9
History
Roof Assessment
Knox Roofing LLC
Excellent condition. No repairs needed.
Comprehensive Assessment
Michael Martin, TREC #20835
57 items identified. Full TREC inspection.
HVAC Filter Change
Scheduled
Next Annual Assessment
Scheduled
Systems Registry
| System | Type | Year | Status |
|---|---|---|---|
| Roof | Concrete S-tile | Original | Excellent |
| HVAC Down | Daikin 3-ton VRV | 2023 | Needs Service |
| HVAC Up | Daikin 4-ton VRV | 2021 | Needs Service |
| HVAC West | Daikin 2.5-ton VRV | 2017 | Needs Service |
| WH 1 | Rinnai Tankless | — | Good |
| WH 2 | Rinnai Tankless | — | Good |
| WH 3 | Bradford White 6-gal | 2011 | Replace |